Tii Technologies · Fiber Optic Products
Fiber Interface Devices / Slack Storage Terminals
Fiber Interface Device / Slack Storage Units are compact enclosures that provide connectivity between the OSP fiber drop and the customer fiber drop, plus slack storage at the demarcation point. Enclosures are available in a range of sizes accommodating up to 12 fiber terminations, for indoor and outdoor installation. Custom logo printing is available on all enclosures.
Series on this page
169F 171F 505F 506F 506R 507F 508F 509R
169F Fiber NID Interface Device
The 169F is the smallest member of the FISS family: a compact enclosure providing a demarcation and transition point between the fiber drop cable and the customer premise fiber. Its internal fiber routing system maintains proper bend radius and stores slack of bend-insensitive fiber. Designed to pair with Tii’s 169 Series sealed terminal platform.
| Dimensions (H × W × D) | 5.45″ × 4.33″ × 2.57″ (13.84 cm × 11.00 cm × 6.53 cm) |
|---|---|
| Adapter types | SC or LC (UPC/APC) |
| Port count | 1, 2, 4 (LC-8) |
| Mounting | Indoor/Outdoor Wall |
| Markets | FTTP, PON, DOT |
| Slack storage | Cable management for small-radius, bend-insensitive fibers |
| Splice / splitter | None / None (patch only) |
| Industry standards | cUL-1863, NEMA-3S; meets GR-1361-CORE severe environmental conditions (−40 °C to 80 °C) |
Ordering configurations: see the 169F datasheet in the Documentation Library or call 888-844-4720.
171F Fiber Transition Enclosure
The 171F is a compact enclosure providing a demarcation and transition point between fiber drops and downstream devices. Its optional copper connectivity makes it an ideal interface to the customer premise, small cells, DAS, or G.fast modem devices — and its NEMA-4 / IP-66 rating suits exposed outdoor mounts.
| Dimensions (H × W × D) | 5.43″ × 5.43″ × 2.55″ (13.79 cm × 13.79 cm × 6.48 cm) |
|---|---|
| Adapter types | SC or LC (UPC/APC) |
| Port count | 1, 2, 4 (LC-8) |
| Mounting | Indoor/Outdoor Wall or Pole |
| Markets | FTTx, Wireless, DOT |
| Slack storage | 15 ft of Tii Z1K9R8 (jumper-pigtail) |
| Splice | 4-port patch with 2 fusion splice capacity |
| Splitter | 1×4, 1×8 options |
| Rating / standards | NEMA-4, IP-66, GR-771, GR-2898, cUL-1863; meets GR-1361-CORE severe environmental conditions (−40 °C to 80 °C) |
| Configuration options | Ground stud; split ratio (1×4 or 1×8); splitter quantity |
505F Series Fiber Interface Device / Slack Storage Unit (NEMA-4)
The 505F is Tii’s most versatile compact enclosure, merging the patch and patch-and-splice functionality of the FET2 and 506F Series into a smaller, NEMA-4 rated unit that serves both single-family and small MDU deployments. See 506F vs 505F: which enclosure do I need? for selection guidance.
| Dimensions (H × W × D) | 8.1 in × 5.6 in × 2.6 in (20.57 cm × 14.22 cm × 6.60 cm) |
|---|---|
| Fiber capacity | Up to 12 fibers (up to 24 ports with LC adapters) |
| Applications | Patch, patch & splice, mid-span access, or PON splitter |
| Environment | Indoor or outdoor; NEMA-4 rated |
| Adapter types | SC/APC, SC/UPC, LC/APC, LC/UPC |
505F part-number builder
505F –XX –XX –XX –X –X
| Series (adapter plate) | Adapter type | No. of ports | Configuration options | Grommets (optional) |
|---|---|---|---|---|
01 Fiber Plate (1, 2, or 4 adapters only)02 Fiber Plate (6 adapters)04 Fiber Plate (12 adapters) |
01 SC/APC02 SC/UPC03 LC/APC04 LC/UPC |
01 1 · 02 2 · 04 406 6 · 12 1224 24 (LC only) |
N NoneE External ground |
None = 2 standard grommetsC 2 conduit grommetsG 1 standard + 1 conduit grommet (1/2″)P 1 conduit grommet (1/2″) + 1 compression grommet |
Example: 505F-01-01-04-N = 505F, fiber plate, SC/APC adapters, 4 ports, no configuration options, standard grommets.
506F Series Fiber Interface Device / Slack Storage Unit
The 506F provides demarcation between the OSP fiber drop and customer fiber drop with generous slack storage, in a compact indoor/outdoor housing configurable from 1 to 24 ports.
| Dimensions (H × W × D) | 10.4 in × 9.9 in × 2.9 in (26.41 cm × 25.14 cm × 7.36 cm) |
|---|---|
| Fiber capacity | Up to 12 fibers (up to 24 ports with LC adapters) |
| Slack storage | Up to 50 ft of customer drop fiber |
| Environment | Indoor or outdoor |
| Adapter types | SC-APC, SC-UPC, LC/APC, LC/UPC |
| Cover option | Gasketed cover available — order as 506G (change “F” to “G”) |
506F part-number builder
506F –XX –XX –XX –X –X
| Series (adapter plate) | Adapter type | No. of ports | Configuration options | Grommets (optional) |
|---|---|---|---|---|
01 Fiber Plate (1, 2, or 4 adapters only)02 Fiber Plate (6 adapters)04 Fiber Plate (12 adapters) |
01 SC-APC02 SC-UPC03 LC/APC04 LC/UPC |
01 1 · 02 2 · 04 406 6 · 12 1224 24 (LC only) |
N NoneC Cable entry clampE External groundD External ground and cable entry clamp installed |
None = 2 standard grommetsC 2 conduit grommetsG 1 standard + 1 conduit grommet (3/4″)P 1 conduit grommet (3/4″) + 1 compression grommet |
Example: 506F-01-01-04-N = 506F, fiber plate, SC-APC adapters, 4 ports, no configuration options, standard grommets.
| Part number | Description |
|---|---|
506F-GRM-KIT |
Grommets for 506F, standard grommet (2 ea.) |
506F-CMP-GRM-KIT |
Grommets for 506F, 1/2″ compression entry (2 ea.) |
506F-CON-GRM-KIT1/2 |
Grommets for 506F, 1/2″ conduit entry (2 ea.) |
506F-CON-GRM-KIT3/4 |
Grommets for 506F, 3/4″ conduit entry (2 ea.) |
FP2R-K9-01-01-100-1 |
Fiber spooling system with 100 ft of flat bend-insensitive MicroDrop cable, for use with 506F |
506R Series Reeled Fiber Dispenser
The 506R provides demarcation between the fiber drop and customer distribution fiber, shipped preloaded with up to 125 feet of pre-connectorized Peelable Indoor/Outdoor MicroDrop fiber stored on a rotating reel for distribution into the home — dispensing to length on site for a fast FTTH deployment with no field connectorization.
| Dimensions (H × W × D) | 8.48″ × 9.94″ × 2.50″ (21.54 cm × 25.25 cm × 6.35 cm) |
|---|---|
| Adapter type | SC (UPC/APC) |
| Port count | 2 |
| Mounting | Indoor/Outdoor Wall or Pole |
| Markets | FTTP, MDU, DOT |
| Reel capacity | Preloaded with up to 125 ft of pre-connectorized MicroDrop distribution fiber |
| Splice | 2 fusion splice capacity (3 mm sleeve holders on lower plate) |
| Industry standards | GR-771, GR-409, GR-326, GR-20; meets GR-1361-CORE severe environmental conditions (−40 °C to 80 °C) |
| Configuration options | Cable entry clamp; external ground; optional grommets; pre-peel or no pre-peel, with or without pull sock |
Installation: 506R installation guide (Installation Note P/N 92255802). Compare reeled options: 506R vs 509R in the FISS comparison.
507F Series Fiber Interface Device / Slack Storage Unit
The 507F offers the same patch-and-slack function in a taller, narrower housing, with an optional 1.5″ fiber storage tray configuration.
| Dimensions (H × W × D) | 11.92 in × 8.38 in × 3.19 in (30.3 cm × 21.2 cm × 8.1 cm) |
|---|---|
| Fiber capacity | Up to 12 fibers (up to 24 ports, LC only) |
| Slack storage | Up to 50 ft |
| Adapter types | SC-APC, SC-UPC |
| Storage tray option | 1.5″ fiber storage tray (series option 03) |
507F part-number builder
507F –XX –XX –XX
| Series (adapter plate) | Adapter type | No. of ports |
|---|---|---|
01 Fiber Plate (1, 2, or 4 adapters)02 Fiber Plate (6 adapters)03 1.5″ Fiber Storage Tray04 Fiber Plate (12 adapters) |
01 SC-APC02 SC-UPC |
01 1 · 02 2 · 03 3 · 04 406 6 · 12 12 · 24 24 (LC only) |
508F Series Fiber Interface Device — Rigid Drop / NEMA-4
The 508F is designed for rigid drop fiber installations with up to a 3-inch bend radius, in a NEMA-4 rated housing for harsh outdoor environments.
| Dimensions (H × W × D) | 12.54 in × 8.39 in × 3.19 in (31.9 cm × 21.3 cm × 8.1 cm) |
|---|---|
| Rating | NEMA-4 |
| Designed for | Rigid drop fiber installations, up to 3 in bend radius |
| Adapter types | SC/APC, SC/UPC, LC/APC, LC/UPC |
| Storage tray option | 1.5″ fiber storage tray (adapter plate option 03) |
508F part-number builder
508F –XX –XX –XX –X –X
| Adapter plate | Adapter type | No. of adapters | Configuration options | Grommets (optional) |
|---|---|---|---|---|
01 Fiber Plate (1, 2, or 4 adapters only)02 Fiber Plate (6 adapters)03 1.5″ Fiber Storage Tray04 Fiber Plate (12 adapters) |
01 SC/APC02 SC/UPC03 LC/APC04 LC/UPC |
01 1 · 02 2 · 03 3 · 04 406 6 · 12 12 · 24 24 (LC only) |
N NoneC Cable entry clampE External groundD External ground & cable entry clamp installed |
None = 2 standard grommetsC 2 conduit grommetsG 1 standard + 1 conduit grommet |
| Part number | Description |
|---|---|
508F-GRM-KIT |
Grommets for 508F (2 ea.) |
508F-CON-GRM-KIT |
Grommets for 508F, 1″ conduit entry (2 ea.) |
509R Series Reeled Fiber Interface Enclosure
The 509R combines a fiber reel preloaded with up to 125 ft of connectorized distribution fiber with slack storage for up to 75 ft of OSP flat drop cable, in a NEMA-4 rated enclosure — dispensing pre-connectorized fiber to greatly reduce installation time.
| Dimensions (H × W × D) | 11.9 in × 13.5 in × 3.2 in (30.22 cm × 34.29 cm × 8.12 cm) |
|---|---|
| Rating | NEMA-4 |
| Reel capacity | Preloaded with up to 125 ft of connectorized distribution fiber |
| Slack storage | Up to 75 ft of OSP flat drop cable |
| Cable types | MicroDrop (K9), Duplex (KD) |
509R fiber reel part-number builder
509R –XX –XX –XX –XXX –X X –XX
| Cable type | Adapter type | Adapter qty | Length (ft) | Configuration options | Grommets (optional) | Optional pre-peel |
|---|---|---|---|---|---|---|
K9 MicroDropKD Duplex |
01 SC-APC02 SC-UPC |
01 102 2 |
025 · 050 · 075 · 100 · 125 |
N NoneC Cable entry clampE External groundD External ground and cable entry clamp installed |
None = 4 standard grommetsC 2 conduit + 2 standard (Pos. B–D)G 3 standard + 1 conduit 1/2″ (Pos. B)P 2 standard + 1 conduit 1/2″ (Pos. B) + 1 compression 1/2″ (Pos. D) |
Blank = no pre-peel, no pull sockPE No pre-peel, with pull sock01 1/4″ peel exposed, no pull sock02 1/4″ peel exposed, with pull sock |
509R patch & slack part-number builder
509R –XX –XX –XX –X X
| Adapter mounting options | Adapter type | No. of ports | Configuration options | Grommets (optional) |
|---|---|---|---|---|
01 Fiber Plate (1, 2, or 4 adapters only)02 Fiber Plate (6 adapters)04 Fiber Plate (12 adapters) |
01 SC/APC02 SC/UPC03 LC/APC04 LC/UPC |
01 1 · 02 2 · 04 406 6 · 12 12 · 24 24 (LC only) |
N NoneC Cable entry clampE External groundD External ground and cable entry clamp installed |
None = 2 standard grommetsC 2 conduit grommetsG 1 standard + 1 conduit grommet (1/2″)P 1 conduit grommet (1/2″) + 1 compression grommet |
| Part number | Description |
|---|---|
509R-GRM-KIT |
Grommets for 509R, standard grommet (2 ea.) |
509R-CMP-GRM-KIT1/2 |
Grommets for 509R, 1/2″ compression entry (2 ea.) |
509R-CON-GRM-KIT1/2 |
Grommets for 509R, 1/2″ conduit entry (2 ea.) |
Pricing & availability: please call 888-844-4720 or request a quote. Custom logo printing is available on all enclosures.