Tii Communication Products Catalog
OSP CONNECTOR BLOCKS 58 BUILDING ENTRANCE TERMINALS 888.844.4720 INDOOR/OUTDOOR BET ORDERING INFORMATION - CALL FOR PRICING & AVAILABILITY MODEL NO. DESCRIPTION FSKT-OFBET-18 Pedestal Skirt Kit - 18” for OF BET 25/50/100 Pair FSKT-OFBET-25 Pedestal Skirt Kit - 25” for OF BET 25/50/100 Pair FSKT-OFNID-18 Pedestal Skirt Kit - 18” for OF BET/NID 25/50/100 Pair FSKT-OFNID-25 Pedestal Skirt Kit - 25” for OF BET/NID 25/50/100 Pair FSKT-OM-18 Pedestal Skirt Kit - 18” for OM BET 50/100 Pair FSKT-OM-25 Pedestal Skirt Kit - 25” for OM BET 50/100 Pair ASKT-OFBET Adjustable Pedestal Skirt for OF BET 25/50/100 Pair ASKT-OFNID Adjustable Pedestal Skirt for OF BET/NID 25/50/100 Pair ASKT-OM Adjustable Pedestal Skirt for OM BET 50/100 Pair BET-STK-KIT Stacking Kit with Grommets, Indoor/Outdoor BET and BET/NIDs BET-CONE-GRM Cone Shaped Grommet, Cut To Fit Tightly Over Incoming Drop Cable BET-GRM-KIT Spare 2” Round Grommets for all BETs (4 ea.) BET-LBL-KIT Spare Pair Assignment, Test Probe and IDC Labels (5 ea.) IDC-CAP-R Red Priority Cap for Tool-less IDC (pkg. of 50) IDC-CAP-Y Yellow Priority Cap for Tool-less IDC (pkg. of 50) IDC-ROCKER Replacement Rocker for Tool-less IDC (pkg. of 10) IDC-TC Test Probe with Spade Tip Cord for Tool-less IDC/BET IHD-RACKMNT Mounting Brackets for Mounting IHD BETs in 19” Rack BET ACCESSORY OPTIONS PROTECTIVE SKIRT KITS Aluminum skirt installed below Indoor/Outdoor Fixed Building Entrance Terminals to provide physical protection for cables entering or exiting beneath the enclosure. ADJUSTABLE SKIRT KIT has a Telescoping bracket and skirt to accommodate various BET mounting heights of 2.5-4 feet (lower edge) off of the ground. FIXED SKIRT KIT contains a skirt only accommodating a fixed BET lower edge mounting height of 48” off the ground. IDC-CAP-R IDC-CAP-Y IDC-ROCKER BET-GRM-KIT IDC-TC BET-LBL-KIT Using theTestProbe 1) Unseat theTestProbe from itsholderanduncoilwire 2) ConnectButt Set tobindingpostsofTestProbeHolder 3) Withopenendofprobe facingdownwards,align the 4) Press theprobedownuntil it seatsover IDC probeoveran IDC rockerpaddle rockerpaddle. Anoticeable clickwillbe felt IDCRockerWire Insertion 1. Installation is accomplished using standard Contacts (IDC), are achievedusing gel sealed rockers. 2.Lift the rocker to the full upposition.DONOT stripwires.Hold thewire pair to be terminated between thumb and index finger. Insertwires intowire guides simultaneouslyuntil they bottom-out.While holdingwires in position, terminate rockerby lowering to the fullDOWN position. (SeePictures). 3.Terminateanyadditionalwire pairs as required following the above steps TestProbe BindingPost Connections ASKT-OM FSKT-OFBET-18 BET-STK-KIT BET-CONE-GRM TiiModel # OFSeries 1 2 3 4 5 6 7 8 9 10 11 12 13 26 27 28 29 30 31 32 33 34 35 36 37 38 14 15 16 17 18 19 20 21 22 23 24 25 39 40 41 42 43 44 45 46 47 48 49 50 Listed 56S7 PAIRASSIGNMENTS
Made with FlippingBook
RkJQdWJsaXNoZXIy ODMzODI=